Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.666
Filtrar
1.
J Cardiothorac Surg ; 19(1): 256, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643178

RESUMO

BACKGROUND: The occurrence of pulmonary visceral subpleural hematoma during care of post-cardiopulmonary resuscitation including chest compressions and anticoagulant and antiplatelet therapies is extremely rare. Also, there are few reports of treatment of visceral subpleural hematoma, most of which are treated by lung resection. Here we describe a rare case that pulmonary visceral subpleural hematoma arose during post-cardiopulmonary resuscitation care and was treated by hematoma evacuation. CASE PRESENTATION: A 58-year-old male with no smoking history and, past medical histories of rheumatoid arthritis, chronic atrial fibrillation, hypertension, diabetes, and dyslipidemia developed ventricular fibrillation due to myocardial infarction and fainted. He received bystander cardiopulmonary resuscitation and defibrillation by the ambulance crew and had return of spontaneous circulation. After transfer to our hospital, the patient underwent percutaneous catheter intervention and stenting with a diagnosis of myocardial infarction, followed by anticoagulant and antiplatelet therapies. On the 8th hospital day, chest radiography suggested right lower lobe pneumonia, and subsequent chest computed tomography revealed pulmonary hematoma in the visceral subpleural area from S6 to S10. Since no improvement was observed in hypoxemia, treatment was considered necessary. First, an attempt at computed tomography-guided drainage of hematoma was made, but insertion of the Pig-tail catheter was difficult due to hardness of the hematoma. Next, evacuation of hematoma was performed on the 13th hospital day. The hematoma was located in the visceral subpleural area and was removed by incising the pleura. TachoSil Tissue Sealing sheet and Polyglycoal acid sheet were applied to the sites of air leakage and oozing after hematoma evacuation. No re-bleeding or air leakage was observed after the treatment, and the patient was discharged on the 26th hospital day after an uneventful course. CONCLUSIONS: Pulmonary visceral subpleural hematoma may occur during post-cardiopulmonary resuscitation care, including chest compressions and anticoagulant and antiplatelet therapies. In our case, CT-guided puncture and drainage was difficult and surgical treatment by incision of the visceral pleura and hematoma evacuation alone was done successfully.


Assuntos
Reanimação Cardiopulmonar , Infarto do Miocárdio , Masculino , Humanos , Pessoa de Meia-Idade , Hematoma/etiologia , Hematoma/cirurgia , Massagem Cardíaca , Anticoagulantes
2.
Curr Probl Cardiol ; 49(5): 102485, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38428555

RESUMO

AIM: Sudden cardiac arrest is a significant cause of death worldwide. Good quality cardiopulmonary resuscitation increases patients' survival. Manual cardiopulmonary resuscitation is often ineffective as rescuers may experience physical and mental fatigue. Mechanical cardiopulmonary resuscitation devices are designed to address this issue, providing an automated approach for high-quality resuscitation. In the present comprehensive umbrella review we summarize current evidence on mechanical devices. METHODS: We searched systematic reviews on mechanical devices in MEDLINE/PubMed. Effect estimates were obtained from original reports, including 95% confidence intervals and p values, when applicable and available, focusing on return of spontaneous circulation, survival to discharge or 30 days, survival with good neurological outcome, and resuscitation-related injuries. RESULTS: From 21 potentially pertinent publications, we shortlisted 10 reviews, each including between 5 and 22 studies. AutoPulse, LUCAS, and LUCAS-2 were among the investigated devices. Most reviews concluded toward mechanical devices being similar or better than manual resuscitation for return of spontaneous circulation and 30-days survival. Regarding survival with good neurological function, some reviews lacked data, while the remaining ones reported similar results or worse outcomes in patients undergoing mechanical resuscitation. Focusing on resuscitation-related injuries, data were limited or conflicting with one review reporting higher rates of injuries with mechanical devices, and two others suggesting similar outcomes. CONCLUSIONS: Manual and mechanical cardiopulmonary resuscitation appear to be similar in terms of return of spontaneous circulation and short-term survival. Mechanical devices appear to be associated with higher resuscitation-related injuries, while there are conflicting data in terms of survival with good neurological outcomes. A comprehensive and large dedicated randomized trial is urgently needed.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Parada Cardíaca Extra-Hospitalar , Humanos , Massagem Cardíaca/métodos , Reanimação Cardiopulmonar/métodos , Parada Cardíaca/terapia , Morte Súbita Cardíaca
3.
Am J Emerg Med ; 78: 102-111, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38244243

RESUMO

INTRODUCTION: The widespread incorporation of extracorporeal cardiopulmonary resuscitation (ECPR) for out-of-hospital cardiac arrest requires the delivery of effective and high-quality chest compressions prior to the initiation of ECPR. The aim of this study was to evaluate and compare the effectiveness of mechanical and manual chest compressions until the initiation of ECPR. METHODS: This study was a secondary analysis of the Japanese retrospective multicenter registry "Study of Advanced Life Support for Ventricular Fibrillation by Extracorporeal Circulation II (SAVE-J II)". Patients were divided into two groups, one receiving mechanical chest compressions and the other receiving manual chest compressions. The primary outcome measure was mortality at hospital discharge, while the secondary outcome was the cerebral performance category (CPC) score at discharge. RESULTS: Of the 2157 patients enrolled in the SAVE-J II trial, 453 patients (329 in the manual compression group and 124 in the mechanical compression group) were included in the final analysis. Univariate analysis showed a significantly higher mortality rate at hospital discharge in the mechanical compression group compared to the manual compression group (odds ratio [95% CI] = 2.32 [1.34-4.02], p = 0.0026). Multivariate analysis showed that mechanical chest compressions were an independent factor associated with increased mortality at hospital discharge (adjusted odds ratio [95% CI] = 2.00 [1.11-3.58], p = 0.02). There was no statistically significant difference in CPC between the two groups. CONCLUSION: For patients with out-of-hospital cardiopulmonary arrest who require ECPR, extreme caution should be used when performing mechanical chest compressions.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca Extra-Hospitalar , Humanos , Massagem Cardíaca , Parada Cardíaca Extra-Hospitalar/terapia , Alta do Paciente , Fibrilação Ventricular/terapia , Estudos Retrospectivos
4.
Eur J Cardiovasc Nurs ; 23(1): 11-20, 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-37154435

RESUMO

AIMS: Individual studies that investigated the effect of standalone audio-visual feedback (AVF) devices during laypersons' cardiopulmonary resuscitation (CPR) training have yielded conflicting results. This review aimed to evaluate the effect of standalone AVF devices on the quality of chest compressions during laypersons' CPR training. METHOD AND RESULT: Randomized controlled trials of simulation studies recruiting participants without actual patient CPR experience were included. The intervention evaluated was the quality of chest compressions with standalone AVF devices vs. without AVF devices. Databases, such as PubMed, Cochrane Central, Embase, Cumulative Index to Nursing & Allied Health Literature (CINAHL), Web of Science, and PsycINFO, were searched from January 2010 to January 2022. The risk of bias was assessed using the Cochrane risk of bias tool. A meta-analysis alongside a narrative synthesis was used for examining the effect of standalone AVF devices.Sixteen studies were selected for this systematic review. A meta-analysis revealed an increased compression depth of 2.22 mm [95% CI (Confidence Interval), 0.88-3.55, P = 0.001] when participants performed CPR using the feedback devices. Besides, AVF devices enabled laypersons to deliver compression rates closer to the recommended range of 100-120 per min. No improvement was noted in chest recoil and hand positioning when participants used standalone AVF devices. CONCLUSION: The quality of the included studies was variable, and different standalone AVF devices were used. Standalone AVF devices were instrumental in guiding laypersons to deliver deeper compressions without compromising the quality of compression rates. However, the devices did not improve the quality of chest recoil and placement of the hands. REGISTRATION: PROSPERO: CRD42020205754.


Assuntos
Reanimação Cardiopulmonar , Humanos , Reanimação Cardiopulmonar/educação , Massagem Cardíaca/métodos , Retroalimentação Sensorial
6.
Sci Rep ; 13(1): 22763, 2023 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-38123619

RESUMO

The objective of this study was to determine the height of optimal hand position for chest compression during adult cardiopulmonary resuscitation (CPR) from the tip of the sternal xiphoid process (TOX) along with the relative heights of the left ventricular outflow tract (LVOT) and abdominal organs among the Thai population. The retrospective cross-sectional study was conducted through a review of medical records and contrast-enhanced chest computed tomography. The total of 204 Thai patients without obvious chest deformity at Ramathibodi Hospital from January to June 2018 was included as part of a multi-regional study. The heights of the level of maximal LV width (LVmax), LOVT, top of liver and stomach with respect to TOX were measured on midline sagittal image. Mean age and body mass index (BMI) were 59.5 years and 23.9 kg/m2, respectively. One hundred and one subjects (49.5%) had pulmonary diseases. Mean height of the LVmax from TOX was 37.7 mm, corresponding to 20% of the sternal length (SL) in the inspiration arm raised position (IAR). The adjusted height of LVmax from TOX in the expiration arm-down position (EAD) was 89.7 mm (48% of SL). The inter-nipple line was at 84.5 mm (45.1% of SL) from TOX on IAR. Among 178 and 109 subjects whose uppermost part of the liver and stomach were above TOX, 80.4% and 94.5% were located within the lower half of the sternum, respectively. The adjusted optimal hand position for chest compression during CPR was at approximately 89.7 mm from TOX in EAD (48% of SL). The hand position at the upper part of the lower half of the sternum is closest to the adjusted LVmax and has a better chance to avoid compression of intraabdominal organs.Trial registration This trial was retrospectively registered on 2 February 2023 in the Thai Clinical Trial Registry, identification number TCTR 20230202006.


Assuntos
Reanimação Cardiopulmonar , Adulto , Humanos , Reanimação Cardiopulmonar/métodos , Estudos Transversais , Massagem Cardíaca/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Pessoa de Meia-Idade
7.
Scand J Trauma Resusc Emerg Med ; 31(1): 57, 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37872558

RESUMO

BACKGROUND: Cardiopulmonary resuscitation (CPR) during hyperbaric oxygen therapy (HBOT) presents unique challenges due to limited access to patients in cardiac arrest (CA) and the distinct physiological conditions present during hyperbaric therapy. Despite these challenges, guidelines specifically addressing CPR during HBOT are lacking. This review aims to consolidate the available evidence and offer recommendations for clinical practice in this context. MATERIALS AND METHODS: A comprehensive literature search was conducted in PubMed, EMBASE, Cochrane Library, and CINAHL using the search string: "(pressure chamber OR decompression OR hyperbaric) AND (cardiac arrest OR cardiopulmonary resuscitation OR advanced life support OR ALS OR life support OR chest compression OR ventricular fibrillation OR heart arrest OR heart massage OR resuscitation)". Additionally, relevant publications and book chapters not identified through this search were included. RESULTS: The search yielded 10,223 publications, with 41 deemed relevant to the topic. Among these, 18 articles (primarily case reports) described CPR or defibrillation in 22 patients undergoing HBOT. The remaining 23 articles provided information or recommendations pertaining to CPR during HBOT. Given the unique physiological factors during HBOT, the limitations of current resuscitation guidelines are discussed. CONCLUSIONS: CPR in the context of HBOT is a rare, yet critical event requiring special considerations. Existing guidelines should be adapted to address these unique circumstances and integrated into regular training for HBOT practitioners. This review serves as a valuable contribution to the literature on "CPR under special circumstances".


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Oxigenoterapia Hiperbárica , Humanos , Parada Cardíaca/terapia , Massagem Cardíaca , Fibrilação Ventricular , Guias de Prática Clínica como Assunto
8.
J Am Heart Assoc ; 12(20): e029457, 2023 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-37830329

RESUMO

Background High-quality cardiopulmonary resuscitation (CPR) is associated with improved survival from out-of-hospital cardiac arrest and includes chest compression depth, chest compression rate, and chest compression fraction within international guideline recommendations. Previous studies have demonstrated divergent results of real-time feedback on CPR performance and patient outcomes. This study investigated the association between emergency medical service CPR quality and real-time CPR feedback for out-of-hospital cardiac arrest. Methods and Results This study collected out-of-hospital cardiac arrest data within the Capital Region of Denmark and compared CPR quality delivered by ambulance personnel. Data were collected in 2 consecutive phases from October 2018 to February 2020. Median chest compression depth was 6.0 cm (no feedback) and 5.9 cm (real-time feedback) (P=0.852). Corresponding proportion of guideline-compliant chest compressions for depth was 16.6% and 28.7%, respectively (P<0.001). Median chest compression rate per minute was 111 and 109 (P<0.001), respectively. Corresponding guideline adherence proportion for compression rate was 65.4% compared with 80.4% (P<0.001), respectively. Chest compression fraction was 78.9% compared with 81.9% (P<0.001), respectively. The combination of guideline-compliant chest compression depth and chest compression rate simultaneously was 8.5% (no feedback) versus 18.8% (feedback) (P<0.001). Improvements were not significant for return of spontaneous circulation (odds ratio [OR], 1.08 [95% CI, 0.84-1.39]), sustained return of spontaneous circulation (OR, 1.00 [95% CI, 0.77-1.31]), or survival to hospital discharge (OR, 0.91 [95% CI, 0.64-1.30]). Conclusions Real-time feedback was associated with improved guideline compliance for chest compression depth, rate, and fraction but not return of spontaneous circulation, sustained return of spontaneous circulation, or survival to hospital discharge. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT04152252.


Assuntos
Reanimação Cardiopulmonar , Serviços Médicos de Emergência , Parada Cardíaca Extra-Hospitalar , Humanos , Parada Cardíaca Extra-Hospitalar/diagnóstico , Parada Cardíaca Extra-Hospitalar/terapia , Reanimação Cardiopulmonar/métodos , Massagem Cardíaca/métodos , Ambulâncias , Retroalimentação , Fatores de Tempo , Serviços Médicos de Emergência/métodos
12.
PLoS One ; 18(2): e0279056, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36735661

RESUMO

INTRODUCTION: The effectiveness of cardiopulmonary resuscitation is determined by appropriate chest compression depth and rate. The American Heart Association recommended CC depth at 5-6 cm to indicate proper cardiac output during cardiac arrest. However, many studies showed the differences in the body builds between Caucasians and Asians. Therefore, this study aimed to determine heart compression fraction (HCF) in the Thai population by using contrast-enhanced computed tomography (CT) scan of the chest and a mathematical model. MATERIALS AND METHODS: Consecutive contrast-enhanced CT scans of the chest performed at Ramathibodi Hospital were retrospectively reviewed from January to March 2018 by two independent radiologists. Patients' characteristics, including gender, age, weight, height, and pre-existing diseases, were recorded, and the chest parameters were measured from a CT scan. The heart compression fraction (HCF) was subsequently calculated. RESULTS: Of 306 subjects, there were 139 (45.4%) males, 148 (47.4%) lung diseases and 10 (3.3%) heart diseases. Mean age and BMI were 60.4 years old and 23.8 kg/m2, respectively. Chest diameter, heart diameter, and non-cardiac soft tissue were significantly smaller in females compared to males. Mean (SD) HCF proportional with 50 mm and 60 mm depth were 38.3% (13.3%) and 50% (14.3%), respectively. There were significant differences of HCF proportional by 50 mm and 60 mm depth between men and women (33.2% vs 42.6% and 44% vs 54.9%, respectively (P<0.001)). In addition, a decrease in HCF was significantly observed among higher BMI groups. CONCLUSION: The CT scan and mathematical model showed that 38% and 50% HCF proportions were generated by 50 mm and 60 mm CC depth. HCF proportions were significantly different between genders and among BMI groups. The recommended depth of 5-6 cm is likely to provide sufficient CC depth in the population of Thailand.


Assuntos
Tamponamento Cardíaco , Reanimação Cardiopulmonar , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Estudos Transversais , Massagem Cardíaca/métodos , População do Sudeste Asiático , Tailândia , Reanimação Cardiopulmonar/métodos , Tomografia Computadorizada por Raios X/métodos
13.
Arch Dis Child Fetal Neonatal Ed ; 108(2): 200-203, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35135850

RESUMO

BACKGROUND: Current neonatal resuscitation guidelines recommend that chest compressions (CCs) be delivered at a rate of 90/min. The aim of the study was to investigate the haemodynamic effects of different CC rates in a neonatal piglet model. METHODS: Six asphyxiated piglets were randomised to CC with rates of 60/min, 90/min, 120/min, 150/min and 180/min for 1 min at each rate. CCs superimposed with sustained inflations were performed with an automated CC machine. RESULTS: Six newborn piglets (age 0-3 days, weight 2.0-2.3 kg) were included in the study. Overall, there was a gradual increase in stroke volume, minimum and maximum rate of left ventricle pressure change (dp/dtmin and dp/dtmax), and carotid blood flow until CC rate of 150/min, with a level-off effect at a CC rate of 180/min. However, cardiac output continued to increase with the highest being at a CC rate of 180/min. CONCLUSION: Rate of CC was associated with changes in haemodynamic parameters during cardiopulmonary resuscitation. CC rate of 150-180/min during CC resulted in the highest cardiac output and arterial blood pressure. TRIAL REGISTRATION NUMBER: Preclincialtrials.eu PCTE0000249.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Animais , Animais Recém-Nascidos , Reanimação Cardiopulmonar/métodos , Massagem Cardíaca/métodos , Hemodinâmica/fisiologia , Suínos
17.
Am J Emerg Med ; 61: 163-168, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36148735

RESUMO

BACKGROUND: Paediatric out-of-hospital cardiac arrest (OHCA) is the reason for an emergency call in approximately 8/100,000 person-years. Improvement of OHCA resuscitation needs a quality chain of survival and a rapid start of resuscitation. The aim of this study was to compare the efficacy of two resuscitation techniques provided on a mannequin, the two-fingers technique (TFT) and the two-thumbs encircling hand technique (TTHT), explained by a trained emergency call responder on the phone in a population of non-health professionals. METHODS: We conducted a randomised crossover study in the simulation lab of a University Hospital. The participants included in the study were non-health professional volunteers of legal age. The participants were assigned (1:1 ratio) to two groups: group A: TFT then TTHT, group B: TTHT then TFT. Scenario and techniques were discovered during the evaluation. RESULTS: Thirty-five volunteers were randomised before the sessions and 33 ultimately came to the simulation lab. We found a better median QCPR global score during TTHT sessions than during TFT sessions (74 vs. 59, P = 0.046). Linear mixed models showed that the TTHT method was the only variable associated with a better QCPR global score [model 1: ß = 14.3; 95% confidence interval (CI), 2.4-26.2; model 2: ß = 14.5; 95% CI, 2.5-26.6]. CONCLUSION: Our study showed the superiority of TTHT for infant CPR performed by non-health professionals when an emergency call responder advised them over the phone. It seemed to be the best technique for a solo rescuer regardless of previous training.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca Extra-Hospitalar , Humanos , Lactente , Criança , Reanimação Cardiopulmonar/métodos , Polegar , Estudos Cross-Over , Massagem Cardíaca/métodos , Manequins , Parada Cardíaca Extra-Hospitalar/terapia
18.
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue ; 34(6): 670-672, 2022 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-35924529

RESUMO

Chest compressions are a key component of cardiopulmonary resuscitation (CPR). The determination of the optimal compression point (OCP) in adult CPR is an indispensable critical factor for high quality chest compressions (CCs). At present, the OCP for adult CPR is still controversial, which still needs further research and discussion. To provide theoretical reference for determining the OCP, this paper reviews the research progress of the OCP of adult CPR from the development process of compression point and hemodynamic mechanism, so as to improve the quality of CCs and the outcome of cardiac arrest (CA) patients.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Adulto , Parada Cardíaca/terapia , Massagem Cardíaca , Hemodinâmica , Humanos , Pressão
19.
J Emerg Med ; 63(1): e17-e21, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35940985

RESUMO

BACKGROUND: Although high-quality chest compressions are an essential, lifesaving component of cardiopulmonary resuscitation, injuries are common with both manual and mechanical chest compressions. CASE REPORT: We discuss the case of a 77-year-old woman who sustained thoracic vertebral fractures after cardiopulmonary resuscitation involving both manual and mechanical chest compressions. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Routine post-cardiac arrest care should include evaluation for chest compression-related injury. If a patient has back pain, focal vertebral tenderness, or paraplegia after chest compressions, imaging to evaluate for vertebral fracture should be performed. If unable to assess for back pain or tenderness, consider imaging to evaluate for vertebral fracture in patients with kyphosis or osteopenia, as these patients are at higher risk for chest compression vertebral injury.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Parada Cardíaca Extra-Hospitalar , Fraturas da Coluna Vertebral , Traumatismos Torácicos , Idoso , Reanimação Cardiopulmonar/efeitos adversos , Reanimação Cardiopulmonar/métodos , Feminino , Parada Cardíaca/complicações , Parada Cardíaca/terapia , Massagem Cardíaca/métodos , Humanos , Parada Cardíaca Extra-Hospitalar/complicações , Fraturas da Coluna Vertebral/complicações , Corpo Vertebral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...